I-1: more than 16 residents (not counting staff) living 24 hours in a supervised setting with custodial care, such as assisted living and group homes; Condition 1 or 2 and Section 420.
I-2: 24-hour medical care for more than five people who can't save themselves, such as hospitals, nursing homes, psychiatric hospitals, detox and foster care facilities.
Construction documents show member sizes and locations and the design loads in 1603.1.1–1603.1.9; conventional light-frame (2308) lists loads, snow, wind, seismic, flood, soil and rain data.
The owner (not the contractor) hires approved agencies for the special inspections in 1705, on top of building official inspections. Not required for minor work, accessory Group U, or conventional light-frame (2308) and prescriptive cold-formed steel construction.
Conventional light-frame construction for buildings within 2308.2 limits; detached one- and two-family homes and townhouses up to three stories use the IRC.
Stud size and spacing per Table 2308.9.1: 2×4 at 24 in for roof only, 16 in with one floor; 2×6 at 24 in with one floor, 16 in with two; 10 ft max height.
Ceiling joists or rafter ties (4 ft max spacing) tie rafters across the building with heel nailing per Table 2308.11.3.1; otherwise the ridge needs a beam.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.
Check your plans against these codes
Start an application and get every flag with its section and fix.