44 sections matching “R602.10” for San Antonio, TX, the 2024 IRC and IBC

  • R602.10

    Wall Bracing

    Used in checks
    • Houses are braced per R602.10 or the simplified method; any part that doesn't fit is engineered.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.3

    Required Length of Bracing

    • Required bracing length per line comes from the wind table (and the seismic table in SDC D or for SDC C townhouses), times the adjustment factors; only parallel panels count.
    • Wind bracing grows with exposure (C x1.2-1.4, D x1.5-1.7), taller roofs and walls and more wall lines; dropping interior gypsum adds 40%, and skipping horizontal blocking doubles it.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.4

    Construction Methods for Braced Wall Panels

    • Bracing methods range from let-in braces and diagonal boards to panels, gypsum, plaster, hardboard and portal frames; panel bracing is at least 3/8 in, nailed 6 in edge and 12 in field.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.5

    Minimum Length of a Braced Wall Panel

    • Most braced panels are at least 48 in long on 8 to 10 ft walls, 53 in at 11 ft and 58 in at 12 ft; let-in braces need 55 to 69 in.
    • Portal frames can be as narrow as 16 to 30 in by header height; ABW panels 28 to 42 in in SDC A-C.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.7

    Ends of Braced Wall Lines With Continuous Sheathing

    • Each end of a continuously sheathed braced wall line uses one of the end conditions in Figure R602.10.7.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.8

    Braced Wall Panel Connections

    • Braced panels tie into the floor through a rim, band or blocking under the full panel length, or full-depth blocking at 16 in where joists run parallel.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.9

    Braced Wall Panel Support

    • Cantilevered joists may carry braced panels; post or pier floors under them are engineered; short masonry stem walls of 48 in or less are reinforced per Figure R602.10.9.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.10

    Cripple Wall Bracing

    • Cripple walls are braced like the wall above, with 15% more length; in SDC D0/D1 and SDC C townhouses only panel methods, with panels no more than 14 ft apart.
    • Cripple walls 48 in or shorter can count as the first story; if any part is taller, the cripple wall is an extra story.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.1.2

    Location of Braced Wall Lines and Permitted Offsets

    • Braced wall lines are straight lines in plan; panels, exterior walls and interior bracing walls may sit up to 4 ft off the line, with no more than two-thirds of the bracing on one side.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.1.3

    Spacing of Braced Wall Lines

    • Parallel braced wall lines are no more than 60 ft apart for wind; seismic limits are 35 ft for SDC C townhouses and 25 ft in SDC D, with allowed stretches to 35 or 50 ft.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.1.4

    Angled Walls

    • A wall along a braced line may angle off for up to 8 ft of diagonal; longer, it becomes its own braced wall line.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.2.1

    Braced Wall Panel Uplift Load Path

    • The wind bracing lengths assume the uplift load path of R602.3.5 is in place.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.2.2

    Locations of Braced Wall Panels

    • The first panel starts within 10 ft of each end of a braced wall line, and panels are no more than 20 ft apart.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.2.3

    Minimum Number of Braced Wall Panels

    • A braced wall line of 16 ft or less needs two panels or one panel of 48 in; longer lines need at least two panels.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.3.1

    Wall Height for Wood Framing

    • For bracing, wall height runs from the bottom of the sole plate to the top of the upper top plate.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.4.1

    Mixing Methods

    • Methods can change from story to story and line to line; mixing on one line is allowed in SDC A-B (and detached C) if the line uses the most demanding method's length.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.4.2

    Continuous Sheathing Methods

    • Continuous sheathing covers every sheathable surface on one side of the line, including above and below openings and gable ends.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.4.3

    Braced Wall Panel Interior Finish Material

    • Braced panels get 1/2 in gypsum on the opposite side (not glued in SDC D), except for GB, BV-WSP, ABW and portal methods, or if the bracing length is increased.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.4.4

    Panel Joints

    • Panel joints land on common studs, and horizontal joints on 1-1/2 in blocking, unless the no-blocking factor is used.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.5.2

    Partial Credit

    • In SDC A-C, panel-type bracing 36 to 48 in long counts for less than its length: 36 in counts as 27 on an 8 ft wall.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.6.1

    Method ABW: Alternate Braced Wall Panels

    • Alternate braced wall (ABW) panels need hold-downs of 1,800 lb for one story or 3,000 lb for the first of two, more for walls over 10 ft.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.6.2

    Method PFH: Portal Frame With Hold-Downs

    • Portal frames with hold-downs (PFH), garage portals (PFG, SDC A-C) and continuous portals (CS-PF) follow their figures; a portal header spans only one opening.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.6.5

    Wall Bracing for Dwellings With Stone and Masonry Veneer in Seismic Design Categories D

    • In SDC D, stone or brick veneer above the first story means BV-WSP bracing (or engineering for townhouses and three-story D2 homes); veneer on the first story only uses normal bracing.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.8.2

    Connections to Roof Framing

    • Braced panels tie to the roof: in SDC A-C no blocking up to 9-1/4 in of heel, blocking up to 15-1/4 in, and blocking panels beyond; in SDC D blocking from the start.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.12.7

    Lateral Support

    • At eave bracing units, the top plate to roof sheathing gap is 9-1/4 in or less unless blocked per R602.10.8.2.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.