  • IBC 407.2

    Corridors continuity and separation

    • I-2 corridors run continuously to exits and are separated per 407.3, except spaces in 407.2.1 to 407.2.6.

    Works withIBC 407.3

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.5

    Smoke barriers

    • Stories with care, treatment or sleeping, or 50+ occupants, split into at least two smoke compartments.

    Works withIBC 709

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.9

    Automatic fire detection

    • Condition 1 corridors and spaces open to them get detection, unless room detectors or door-closer detectors cover it.

    Works withIBC 407.2

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.10

    Secured yards

    • Fenced, locked grounds need dispersal areas 50 ft from the building: 30 sq ft per bed patient, 6 per other.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.11

    Electrical systems

    • Essential electrical systems per Chapter 27 and NFPA 99.

    Works withIBC Chapter 27

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.2.1

    Waiting and similar areas

    • Waiting and meeting areas may open to corridors if not sleeping, treatment or hazardous, with detection and clear exit access.

    Works withIBC 907IBC 903.3.2

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.2.2

    Care providers' stations

    • Nurses' stations and charting areas may open to corridors.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.2.3

    Psychiatric treatment areas

    • Supervised psychiatric areas up to 1,500 sq ft may open to corridors, one per smoke compartment, with detection.

    Works withIBC 907.2

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.2.5

    Nursing home housing units

    • In I-2 Condition 1 nursing units, shared living spaces may open to corridors with detection or quick-response sprinklers.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.2.6

    Nursing home cooking facilities

    • Domestic kitchens may open to corridors serving 30 or fewer residents, one per smoke compartment.

    Works withIBC 407.2.7

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.2.7

    Domestic cooking appliances

    • Domestic cooking limited to ovens, cooktops, ranges, warmers and microwaves, with hood, cooktop suppression, staff shutoff, 120-minute timer and an extinguisher within 30 ft.

    Works withIBC 904.15IBC 906

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.3.1

    Corridor doors

    • Corridor doors needn't be rated or self-closing but must resist smoke and latch positively (no roller latches).

    Works withIBC 716

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.4.1

    Direct access to a corridor

    • Habitable rooms open directly to a corridor, except rooms exiting outside at grade or in care suites.

    Works withIBC 407.4.4

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.4.2

    Distance of travel

    • Travel within a sleeping room to its exit door is limited to 50 ft.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.4.3

    Projections in nursing home corridors

    • In 96-in corridors, fixed furniture may leave 72 in clear, on one side, 50 sq ft groups 10 ft apart.

    Works withIBC 1005.7

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.5.1

    Smoke compartment size

    • Smoke compartments up to 22,500 sq ft; 40,000 in Condition 2 with single-patient rooms or no sleeping rooms.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.5.2

    Exit access travel distance

    • Travel to a smoke barrier door is limited to 200 ft.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.5.3

    Refuge area

    • Each compartment holds the neighbors' occupants: 30 net sq ft per bed or stretcher patient, 6 sq ft per other person.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.5.4

    Independent egress

    • Each compartment has egress without going back through the origin compartment; compartments without an exit reach two others.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.6.1

    Activation of automatic-closing doors

    • Hold-open doors also close on fire alarm or sprinkler flow; one release closes all in the compartment.

    Works withIBC 716.2.6.6

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.3.1.1

    Door construction

    • Unrated corridor doors fit closely with stops; Dutch doors latch both halves; louvers or ¾-in undercut allowed for makeup air.

    Works withIBC 1020.6

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.4.4.1

    Exit access through care suites

    • Other areas may not exit through a care suite.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.4.4.3

    Access to corridor

    • Each care suite has a door to a corridor or horizontal exit within 100 ft of travel.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.4.4.4

    Circulation paths within a care suite

    • Paths within a care suite are at least 36 in wide.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.4.4.6

    Care suites containing sleeping room areas

    • Sleeping suites serve 8 or fewer beds, allow constant visual supervision, or have smoke detection.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.4.4.7

    Care suites not containing sleeping rooms

    • Treatment-only suites follow 407.4.4.7.1 and 407.4.4.7.2.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.4.4.6.1

    Area

    • Sleeping suites up to 7,500 sq ft, or 10,000 with smoke detection.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.4.4.7.1

    Area

    • Treatment suites up to 12,500 sq ft, or 15,000 with smoke detection.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 202

    Care suite

    • In Group I-2, a group of treatment and sleeping rooms with support and circulation space, where staff supervise all care recipients, meeting 407.4.4.

    Works withIBC 407.4.4

    International Building Code, 2024 · Chapter 2, DefinitionsRead the full text (opens UpCodes in a new tab)

  • IBC 1402.2

    Weather protection

    • Exterior walls need a weather-resistant assembly: flashing, a water-resistive barrier behind the veneer and a way to drain water out. Not needed over concrete or masonry walls; drainage can be skipped if an ASTM E331 test (4×8 ft sample, 6.24 psf, 2 hours) shows no leaks; EIFS per 1407.4.1.

    Works withIBC 1403.2IBC 1404.3IBC 1404.4IBC 1407.4.1

    International Building Code, 2024 · Chapter 14, Exterior WallsRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application