51 sections matching “IBC 403” for San Antonio, TX, the 2024 IRC and IBC IBC 403.1
IBC 403.2
IBC 403.3
Automatic sprinkler system High-rises are fully sprinklered, with a secondary water supply where 403.3.3 requires; telecom equipment spaces with detection and rated separation are excepted. Works with IBC 903.3.1.1 IBC 403.3.3
International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and Use Read the full text (opens UpCodes in a new tab)
IBC 403.4
Emergency systems High-rise detection, alarm and emergency systems follow 403.4.1 to 403.4.8. International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and Use Read the full text (opens UpCodes in a new tab)
IBC 403.5
IBC 403.6
IBC 403.2.1
Reduction in fire-resistance rating Rating reductions apply where every floor has supervised sprinkler valves and waterflow devices. International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and Use Read the full text (opens UpCodes in a new tab)
IBC 403.2.2
Structural integrity of interior exit stairways and elevator hoistway enclosures Risk Category III/IV high-rises and buildings over 420 ft need impact-resistant stair and hoistway enclosures. Works with IBC 1604.5
International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and Use Read the full text (opens UpCodes in a new tab)
IBC 403.2.3
Sprayed fire-resistive materials (SFRM) SFRM bond strength: 430 psf up to 420 ft, 1,000 psf above. International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and Use Read the full text (opens UpCodes in a new tab)
IBC 403.3.1
IBC 403.3.2
Water supply to required fire pumps Over 420 ft (or IV-A/IV-B over 120 ft), fire pumps connect to two mains in different streets. International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and Use Read the full text (opens UpCodes in a new tab)
IBC 403.3.3
Secondary water supply High-rises in Seismic Design Category C–F need an on-site secondary supply lasting 30 minutes. Works with IBC 1613
International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and Use Read the full text (opens UpCodes in a new tab)
IBC 403.3.4
IBC 403.4.1
IBC 403.4.2
IBC 403.4.3
IBC 403.4.4
IBC 403.4.5
Emergency communication coverage Two-way emergency responder radio coverage per IFC 510. Works with IFC
International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and Use Read the full text (opens UpCodes in a new tab)
IBC 403.4.6
IBC 403.4.7
Smoke removal Post-fire smoke removal by operable panels (40 sq ft per 50 ft of perimeter), mechanical exhaust of one air change per 15 minutes, or an approved equal. International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and Use Read the full text (opens UpCodes in a new tab)
IBC 403.4.8
IBC 403.5.1
Remoteness of interior exit stairways Exit stairs are at least 30 ft or one-quarter of the diagonal apart, whichever is less; scissor stairs count as one. International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and Use Read the full text (opens UpCodes in a new tab)
IBC 403.5.2
IBC 403.5.3
Stairway door operation Stair doors may lock from the stair side if they unlock from the fire command center, on fire alarm, and on power failure. International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and Use Read the full text (opens UpCodes in a new tab)
IBC 403.5.4
IBC 403.5.5
IBC 403.6.1
IBC 403.6.2
IBC 403.2.1.1
Type of construction Up to 420 ft, Type IA may drop to IB ratings (not floor-supporting columns); IB may drop to IIA except in F-1, H-2, H-3, H-5, M and S-1; height and area stay the same. Works with IBC 601
International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and Use Read the full text (opens UpCodes in a new tab)
IBC 403.2.1.2
Shaft enclosures Up to 420 ft, non-exit, non-hoistway shafts may be 1-hour if sprinklered at top and alternate floors. International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and Use Read the full text (opens UpCodes in a new tab)
IBC 403.2.2.1
Wall assembly materials Enclosure walls need impact-resistant panels meeting ASTM C1629 levels (two layers at Soft 2/Hard 2, or one at Soft 2/Hard 3). International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and Use Read the full text (opens UpCodes in a new tab)
IBC 403.2.2.2
IBC 403.2.2.3
IBC 403.2.2.4
IBC 403.3.1.1
Buildings 420 feet or less in height One standpipe or express riser per vertical zone. International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and Use Read the full text (opens UpCodes in a new tab)
IBC 403.3.1.2
Buildings more than 420 feet in height At least two risers per zone, feeding alternate floors. International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and Use Read the full text (opens UpCodes in a new tab)
IBC 403.3.1.3
IBC 403.4.8.1
Equipment room Indoor generators go in 2-hour rooms with supervision and manual start at the fire command center. International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and Use Read the full text (opens UpCodes in a new tab)
IBC 403.4.8.2
Fuel line piping protection Generator fuel lines are protected by 2-hour systems or assemblies (1 hour if sprinklered). International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and Use Read the full text (opens UpCodes in a new tab)
IBC 403.4.8.3
IBC 403.4.8.4
Emergency power loads Emergency loads: exit signs and egress lighting, elevator car lights, voice alarm, detection, fire alarm, electric fire pumps and fire command center. Works with IBC 403.4.6
International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and Use Read the full text (opens UpCodes in a new tab)
IBC 403.5.3.1
Stairway communication system Locked stairs need two-way communication at least every fifth floor, listed to UL 2525. International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and Use Read the full text (opens UpCodes in a new tab)
IBC 2101.2
IBC 2510.6
IBC 3007.1
IBC 412.2.1.2
Structural integrity of interior exit stairways and elevator hoistway enclosures Cabs over 75 ft need 403.2.2 enclosures. Works with IBC 403.2.2
International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and Use Read the full text (opens UpCodes in a new tab)
IBC 412.2.1.3
IBC 412.2.3.3
IBC 508.3.1.1
IBC 2702.2.11
IBC 1407.4.1.1
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.