Skip to content

Search the building code.

Every 2024 IRC section and the IBC as it loads, by number or topic, plus the local rules for your city. Free to search.

Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

A random sample from 9,828 sections for San Antonio, TX, the 2024 IRC and IBC

Show another sample
  • IBC 101.4.1

    Gas

    • Gas piping from the point of delivery and gas appliances follow the International Fuel Gas Code.

    Works withIFGC

    International Building Code, 2024 · Chapter 1, Scope and AdministrationRead the full text (opens UpCodes in a new tab)

  • IBC 421.1

    General

    • Hydrogen fuel gas rooms required by the IFC follow 421.1 to 421.7.

    Works withIFC

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • R330.7

    Fire Detection

    • Spaces with batteries get smoke alarms, or an interconnected heat detector where a smoke alarm can't go.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

  • R1001.11

    Fireplace Clearance

    • Framing and other combustibles stay 2 in from the front and sides and 4 in from the back of a masonry fireplace; the gap is left open except for noncombustible fill or fireblocking.
    • Clearance exceptions: UL 127 zero-clearance listed masonry fireplaces; 12 in from the firebox lining when built into a masonry wall; trim and sheathing edges may abut sidewalls 8 in (12 in for openings of 6 sq ft or more) from the lining.
    • Combustible mantels and trim stay at least 6 in from the opening, and within 12 in of it may project no more than 1/8 in per inch of distance.

    International Residential Code, 2024 · Chapter 10, Chimneys and FireplacesRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application