  • R703.2

    Water-Resistive Barrier

    • Every exterior wall gets at least one continuous water-resistive barrier behind the siding and deck ledgers: No. 15 felt, ASTM E2556 wrap, foam WRB systems or tested alternatives.
    • Felt and house wrap run horizontally, lapped 2 in at horizontal seams and 6 in at vertical joints.
    • Unconditioned sheds and playhouses skip the barrier if the siding is on bare studs, the walls are uninsulated and unfinished inside.

    International Residential Code, 2024 · Chapter 7, Wall CoveringRead the full text (opens UpCodes in a new tab)

  • E4207.1

    Pumps

    • Storable pool filter pumps are double-insulated with an internal EGC and a GFCI in or within 12 in of the plug (NEC 680.31).

    International Residential Code, 2024 · Chapter 42, Swimming PoolsRead the full text (opens UpCodes in a new tab)

  • N1104.2.2

    Specific Locations

    • Lights in garages, unfinished basements, laundry and utility rooms shut off automatically within 20 minutes of vacancy, with a manual switch.

    International Residential Code, 2024 · Chapter 11, Energy EfficiencyRead the full text (opens UpCodes in a new tab)

  • P2903.10.2

    Water Heater Valve

    • Each water heater's cold supply has a readily accessible full-open valve at or near it.

    International Residential Code, 2024 · Chapter 29, Water Supply and DistributionRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.