Tied wythes use one 3/16 in tie per 4-1/2 sq ft (24 in vertical, 36 in horizontal), adjustable ties or joint reinforcement one per 2.67 sq ft at 16 to 24 in, plus ties within 12 in of openings.
Construction joints in concrete walls follow the foundation-wall rule: at supports with No. 4 bars at 24 in across them (plain walls), or mid-span in reinforced walls.
Reuse tanks keep set distances: 2 ft from protected tree roots, 5 ft from lot lines, septic and seepage pits and water service, 10 ft from public mains, 50 ft from wells and streams.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.