A random sample from 4,296 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • R602.10.3

    Required Length of Bracing

    • Required bracing length per line comes from the wind table (and the seismic table in SDC D or for SDC C townhouses), times the adjustment factors; only parallel panels count.
    • Wind bracing grows with exposure (C x1.2-1.4, D x1.5-1.7), taller roofs and walls and more wall lines; dropping interior gypsum adds 40%, and skipping horizontal blocking doubles it.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • M1503.4

    Duct Material

    • Kitchen exhaust ducts are galvanized steel, stainless or copper; downdraft ducts may be Schedule 40 PVC under a slab on grade if fully backfilled, solvent-welded and rising no more than 1 in above the floor and grade.

    International Residential Code, 2024 · Chapter 15, Exhaust SystemsRead the full text (opens UpCodes in a new tab)

  • M1804.1

    Type of Vent Required

    • Appliances use listed vents: Type L for oil appliances listed for it, pellet vents for pellet appliances.

    International Residential Code, 2024 · Chapter 18, Chimneys and VentsRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.