Skip to content

Search the building code.

Every 2024 IRC section and the IBC as it loads, by number or topic, plus the local rules for your city. Free to search.

Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

A random sample from 4,296 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • E3605.6

    Locations Exposed to Direct Sunlight

    • Conductors in direct sun are listed sunlight-resistant or covered with listed sunlight-resistant tape or sleeving (NEC 310.10(D)).

    International Residential Code, 2024 · Chapter 36, ServicesRead the full text (opens UpCodes in a new tab)

  • P2603.5.1

    Sewer Depth

    • Building sewer depths at the septic tank and elsewhere are set by the jurisdiction (the model code leaves the numbers blank).

    Local review: The model code leaves these sewer depths blank for each city to fill in; check San Antonio's adopted values.

    International Residential Code, 2024 · Chapter 26, General Plumbing RequirementsRead the full text (opens UpCodes in a new tab)

  • R602.10.6.5

    Wall Bracing for Dwellings With Stone and Masonry Veneer in Seismic Design Categories D

    • In SDC D, stone or brick veneer above the first story means BV-WSP bracing (or engineering for townhouses and three-story D2 homes); veneer on the first story only uses normal bracing.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R1001.8

    Smoke Chamber

    • Smoke chamber walls are solid masonry, stone or concrete, 8 in total and parged smooth with refractory mortar; 6 in total is enough with a 2 in firebrick or 5/8 in vitrified clay lining.

    International Residential Code, 2024 · Chapter 10, Chimneys and FireplacesRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application