Skip to content

Search the building code.

Every 2024 IRC section and the IBC as it loads, by number or topic, plus the local rules for your city. Free to search.

Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

A random sample from 4,296 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • R403.1.4.1

    Frost Protection

    • Foundations are protected from frost by going below the local frost line, a frost-protected shallow foundation, ASCE 32, or bearing on rock; never on seasonally frozen soil.
    • Frost protection isn't needed for detached light-frame sheds up to 600 sq ft, or other sheds up to 400 sq ft, with eaves of 10 ft or less.

    International Residential Code, 2024 · Chapter 4, FoundationsRead the full text (opens UpCodes in a new tab)

  • M1505.4.1

    System Design

    • A whole-house system is one or more supply or exhaust fans with ducts and controls; local fans can serve, and an outdoor duct to the air handler return counts as supply.

    International Residential Code, 2024 · Chapter 15, Exhaust SystemsRead the full text (opens UpCodes in a new tab)

  • R502.9

    Fastening

    • Floor framing is nailed per Table R602.3(1); post-and-beam supports get positive connections against uplift and sliding.

    International Residential Code, 2024 · Chapter 5, FloorsRead the full text (opens UpCodes in a new tab)

  • E4206.12

    Electric Pool Water Heaters

    • Electric pool heaters split elements into loads of 48 A or less protected at 60 A max, with circuits sized at 125% of nameplate (NEC 680.10).

    International Residential Code, 2024 · Chapter 42, Swimming PoolsRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application