  • P2903.2

    Maximum Flow and Water Consumption

    • Maximum flows: lavatory and sink faucets 2.2 gpm at 60 psi, showerheads (including hand showers) 2.5 gpm at 80 psi, water closets 1.6 gallons per flush.

    International Residential Code, 2024 · Chapter 29, Water Supply and DistributionRead the full text (opens UpCodes in a new tab)

  • R404.1.3.3.7.6

    Alternate Grade of Reinforcement and Spacing

    • Other bar sizes or grades are fine with equal steel area per foot, spaced between half the wall thickness and 48 in.

    International Residential Code, 2024 · Chapter 4, FoundationsRead the full text (opens UpCodes in a new tab)

  • R401.1

    Application

    • This chapter governs foundations and foundation spaces; flood-zone foundations also follow R306, and wood foundations follow AWC PWF.
    • Prescriptive wood foundations are limited to two floors and a roof, with interior walls at most 50 ft apart; in SDC D they must be engineered.

    International Residential Code, 2024 · Chapter 4, FoundationsRead the full text (opens UpCodes in a new tab)

  • R324.4.3

    Glazing in Windows

    • A window pane is hazardous when it's over 9 sq ft, its bottom is under 18 in and its top is over 36 in above the floor, and a walking surface is within 36 in.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.