Skip to content

Search the building code.

Every 2024 IRC section and the IBC as it loads, by number or topic, plus the local rules for your city. Free to search.

Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

A random sample from 4,296 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • M1803.4.2

    Connection to Factory-Built Fireplace Flue

    • Only appliances listed for it may connect to a factory-built fireplace flue.

    International Residential Code, 2024 · Chapter 18, Chimneys and VentsRead the full text (opens UpCodes in a new tab)

  • P2904.6.1

    Method of Sizing Pipe

    • Size by the prescriptive method or NFPA 13D hydraulics; pipe at least 3/4 in and head adapters at least 1/2 in.

    International Residential Code, 2024 · Chapter 29, Water Supply and DistributionRead the full text (opens UpCodes in a new tab)

  • N1101.13

    Application

    • Residential buildings comply by one of four paths: prescriptive, simulated performance, Energy Rating Index, or tropical; work on existing buildings follows N1109.

    Local review: Texas sets a statewide minimum residential energy code and cities adopt their own edition with amendments; confirm the energy code edition San Antonio has adopted before relying on 2024 values.

    International Residential Code, 2024 · Chapter 11, Energy EfficiencyRead the full text (opens UpCodes in a new tab)

  • E3405.3

    Indoor Dedicated Panelboard Space

    • Indoors, the space from floor to 6 ft above a panel (or the structural ceiling) is reserved for electrical; pipes and ducts may run above only with leak protection; lay-in ceilings allowed (NEC 110.26(E)(1)).

    International Residential Code, 2024 · Chapter 34, General RequirementsRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application