Skip to content

Search the building code.

Every 2024 IRC section and the IBC as it loads, by number or topic, plus the local rules for your city. Free to search.

Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

A random sample from 4,296 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • R609.8

    Mullions

    • Mullions are tested to AAMA 450 or engineered, deflect no more than L/175, and hold 1.5 times design load with 0.4% or less permanent set.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • P2903.8

    Size of Water-Service Mains, Branch Mains and Risers

    • Water service is at least 3/4 in; mains and risers are sized from demand, pressure and friction loss by approved methods such as Appendix AP.

    International Residential Code, 2024 · Chapter 29, Water Supply and DistributionRead the full text (opens UpCodes in a new tab)

  • R401.4.1

    Geotechnical Evaluation

    • Without a geotechnical report, assume these soil bearing values; clay and silt default to 1,500 psf, and weaker soil needs an investigation.
    • Soils fall into four groups by drainage and expansion; Group I drains well, Group III is high-expansion clay, and Group IV is organic.

    International Residential Code, 2024 · Chapter 4, FoundationsRead the full text (opens UpCodes in a new tab)

  • R608.6

    Above-Grade Wall Requirements

    • Above-grade concrete wall rebar for wind comes from the tables; add a bar at corners and four No. 4 horizontals (top, bottom and third points), continuous between stories.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application