Skip to content

Search the building code.

Every 2024 IRC section and the IBC as it loads, by number or topic, plus the local rules for your city. Free to search.

Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

A random sample from 4,296 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • N1102.2.11.1

    Crawl Space Wall Insulation Installation

    • Crawl wall insulation runs from the sill to the top of the footing (or the crawl floor if over 24 in below grade), and exposed earth gets a sealed Class I vapor retarder lapped 6 in and run 6 in up the walls.

    International Residential Code, 2024 · Chapter 11, Energy EfficiencyRead the full text (opens UpCodes in a new tab)

  • P3009.10.4

    Excavation and Construction

    • Trench and bed bottoms are level, not dug in soil wet enough to roll a wire, and smeared surfaces are scarified.

    International Residential Code, 2024 · Chapter 30, Sanitary DrainageRead the full text (opens UpCodes in a new tab)

  • E3604.2.1

    Above Roofs

    • Conductors clear roofs by 8 ft, kept for 3 ft past the roof edge; 3 ft on 4:12 or steeper roofs; 18 in over the overhang when no more than 6 ft of conductor passes over 4 ft of roof (NEC 230.24(A)).

    International Residential Code, 2024 · Chapter 36, ServicesRead the full text (opens UpCodes in a new tab)

  • E3902.5

    Basement Receptacles

    • Basement receptacles get GFCI protection, finished or not (NEC 210.8(A)(5)).

    Local review: GFCI coverage here follows the 2023 NEC; confirm San Antonio's adopted NEC edition before relying on the expanded list.

    International Residential Code, 2024 · Chapter 39, Power and Lighting DistributionRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application