Skip to content

Search the building code.

Every 2024 IRC section and the IBC as it loads, by number or topic, plus the local rules for your city. Free to search.

Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

A random sample from 4,296 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • R1006.2

    Exterior Air Intake

    • The air intake draws from outdoors or a naturally vented crawl or attic, not from the garage or basement, sits no higher than the firebox (unless listed), and has a 1/4 in corrosion-resistant screen.

    International Residential Code, 2024 · Chapter 10, Chimneys and FireplacesRead the full text (opens UpCodes in a new tab)

  • R903.2

    Flashing

    • Flash at copings, wall-roof joints, slope or direction changes, openings and where an eave meets a sidewall (kick-out); metal flashing is at least 26-gauge (0.019 in).

    International Residential Code, 2024 · Chapter 9, Roof AssembliesRead the full text (opens UpCodes in a new tab)

  • R1006.5

    Outlet

    • The air outlet is in the back or side of the firebox, or at hearth level within 24 in of the opening, closable and built so embers cannot fall into hidden combustible spaces.

    International Residential Code, 2024 · Chapter 10, Chimneys and FireplacesRead the full text (opens UpCodes in a new tab)

  • R309.2

    One- And Two-Family Dwellings Automatic Sprinkler Systems

    • The model code requires sprinklers in new one- and two-family homes; additions to unsprinklered homes are exempt.

    Local review: Texas law bars cities from requiring sprinklers in one- and two-family homes; confirm San Antonio deletes this before enforcing.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application