Skip to content

Search the building code.

Every 2024 IRC section and the IBC as it loads, by number or topic, plus the local rules for your city. Free to search.

Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

A random sample from 4,296 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • R905.1.1

    Underlayment

    • Shingle, tile, metal, slate, wood and solar roofs get labelled underlayment; in normal-wind areas felt, synthetic or self-adhered types qualify, while wind-design areas need the heavier types.
    • Under shingles, 2:12 to 4:12 roofs get two layers (a half-sheet starter, then sheets lapped half plus 2 in); 4:12 and steeper get one layer lapped 2 in; end laps are 4 in, staggered 6 ft.
    • In wind-design areas, use two fastened layers, 4 in self-adhered strips over deck joints plus underlayment, or full self-adhered; cap nails go in a 12 in grid with 6 in at laps.

    International Residential Code, 2024 · Chapter 9, Roof AssembliesRead the full text (opens UpCodes in a new tab)

  • N1108.2.1.3

    Roof Solar Reflectance Index

    • Low-slope roofs in zones 0-2 earn credit with a 3-year aged SRI of 75 or more over 95 percent of the roof, excluding PV, equipment, shaded and ballasted areas.

    International Residential Code, 2024 · Chapter 11, Energy EfficiencyRead the full text (opens UpCodes in a new tab)

  • E3609.3.2

    Other Means

    • Alternatively, an accessible copper or aluminum busbar at least 1/4 by 2 in with room for three communications terminations (NEC 250.94(B)).

    International Residential Code, 2024 · Chapter 36, ServicesRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application