Intermediate 175-225 F heads are used under skylights, in attics and roof-adjacent concealed spaces, and within set distances of heat sources (e.g. 3-6 in of furnaces, 9-18 in of ranges and ovens).
A window pane is hazardous when it's over 9 sq ft, its bottom is under 18 in and its top is over 36 in above the floor, and a walking surface is within 36 in.
Bath and toilet room exhaust goes directly outdoors, is not recirculated or sent to another unit, and bath and kitchen exhaust never ends in an attic, crawl space or indoors (ductless hoods excepted).
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.