  • M1411.5

    Signs and Identification

    • A2L systems carry a permanent label with the installer's contact details, the refrigerant number and the charge.

    International Residential Code, 2024 · Chapter 14, Heating and Cooling Equipment and AppliancesRead the full text (opens UpCodes in a new tab)

  • R507.9.1.3

    Ledger to Band Joist Details

    • Ledger lag screws and bolts are 1/2 in, spaced per the table by joist span and load, with lag holes drilled 1/2 in through the ledger and 5/16 to 3/8 in into the band.
    • Ledger fasteners stay 2 in from the ledger top and ends and 3/4 in from its bottom, staggered, with rows 1-5/8 to 5 in apart; in the band, 3/4 in from top and 2 in from bottom.

    International Residential Code, 2024 · Chapter 5, FloorsRead the full text (opens UpCodes in a new tab)

  • R318.7.12.1

    Treads of Alternating Tread Devices

    • Alternating tread devices have treads at least 5 in deep (8-1/2 in projected) and 7 in wide, risers up to 9-1/2 in, at 50 to 70 degrees.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

  • E3608.1

    Grounding Electrode System

    • Every electrode present (water pipe, concrete-encased, ground ring, rod/pipe, plate, other listed) is bonded together; if none exist, install one or more (NEC 250.50).

    International Residential Code, 2024 · Chapter 36, ServicesRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.