A random sample from 4,296 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • P2904.3.1

    Nonmetallic Pipe and Tubing

    • CPVC, PEX and PE-RT sprinkler pipe is listed for residential sprinklers.

    International Residential Code, 2024 · Chapter 29, Water Supply and DistributionRead the full text (opens UpCodes in a new tab)

  • E3705.7

    Location of Overcurrent Devices in or on Premises

    • Breakers and fused switches are readily accessible, protected, not in closets, bathrooms or over stairs, with the handle no higher than 6 ft 7 in (NEC 240.24).

    International Residential Code, 2024 · Chapter 37, Branch Circuit and Feeder RequirementsRead the full text (opens UpCodes in a new tab)

  • R101.2

    Scope

    Used in checks
    • The residential code covers dwellings up to 3 stories above grade plane.

    Works withIBC 101.2

    Chapter 1 isn't in the code library yet; confirm this value against the full text.

    International Residential Code, 2024

  • G2452.2

    Installation

    • Gas boilers follow instructions, with permanent operating instructions and nameplate attached, controls tested by the installer and a control diagram left.

    International Residential Code, 2024 · Chapter 24, Fuel GasRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.