  • N1104.1

    Lighting Equipment

    • Permanent luminaires reach at least 45 lumens per watt, or their lamps at least 65; appliance, disinfecting, federally regulated lamps and fixtures of 3 W or less are exempt.

    International Residential Code, 2024 · Chapter 11, Energy EfficiencyRead the full text (opens UpCodes in a new tab)

  • M1307.4.1

    Natural Ventilation

    • Naturally ventilated hydrogen spaces are 850 sq ft max, produce no more than 4 scfm per 250 sq ft, have openings at least 3 in across, and keep ignition sources 12 in below the ceiling.

    International Residential Code, 2024 · Chapter 13, General Mechanical System RequirementsRead the full text (opens UpCodes in a new tab)

  • R607.5

    Panel Support

    • Supports under glass block deflect no more than L/600; panels are anchored at top and sides at 16 in for 200 plf, or held in channels with 1 in of recess.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • E3901.3.1

    Other Outlets Prohibited

    • Small-appliance circuits serve no other outlets except a clock receptacle or gas-range accessory power (NEC 210.52(B)(2)).

    International Residential Code, 2024 · Chapter 39, Power and Lighting DistributionRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.