Skip to content

Search the building code.

Every 2024 IRC section and the IBC as it loads, by number or topic, plus the local rules for your city. Free to search.

Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

A random sample from 4,296 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • M2101.12

    Material Rating

    • Pipe and tubing are rated for the system's temperature and pressure, fittings suit the pipe and pressure, and buried materials are rated for burial.

    International Residential Code, 2024 · Chapter 21, Hydronic PipingRead the full text (opens UpCodes in a new tab)

  • M1401.3

    Equipment and Appliance Sizing

    • Equipment is sized by ACCA Manual S from Manual J loads; multistage or variable units within their published range, or the next size up when no unit meets both total and sensible loads, may exceed Manual S.

    International Residential Code, 2024 · Chapter 14, Heating and Cooling Equipment and AppliancesRead the full text (opens UpCodes in a new tab)

  • R905.8

    Wood Shakes

    • Wood shakes go at 3:12 or steeper, gapped 3/8-5/8 in, interlaid with 18 in No. 30 felt, a doubled starter course, exposure 5-1/2 to 10 in, and valleys 11 in each side.

    International Residential Code, 2024 · Chapter 9, Roof AssembliesRead the full text (opens UpCodes in a new tab)

  • P3005.2.10

    Cleanout Access

    • Cleanouts aren't concealed (plenums, walls, floor-ceilings, below grade, low crawls under 24 in); wall cleanouts sit within 1-1/2 in of the finish, buried ones extend to grade, and floor plugs are flush.

    International Residential Code, 2024 · Chapter 30, Sanitary DrainageRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application