Reduced Energy Use in Service Water-Heating Options
Water heating credits need the tabled UEF: gas storage 0.81 or 0.86, gas tankless 0.92 or 0.95, heat pump 2.20 to 3.75, solar SUEF 3.00 (electric backup) or 1.80 (gas).
Windows, skylights and sliders leak no more than 0.3 cfm/sq ft and swinging doors 0.5, tested to NFRC 400 or AAMA/WDMA/CSA 101 and labelled; site-built units are exempt.
A neutral is brought to lighting switch locations in bathrooms, halls, stairs and habitable rooms (one location if the whole room is visible), with up to 5 electronic switches per circuit and 25 per feeder (NEC 404.2(C)).
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.