A random sample from 4,296 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • M1803.3.4

    Clearance

    • Connector clearances: single-wall 18 in (9 in for Type L oil appliances); Type L pipe 9 in (3 in or listed for Type L oil appliances); reductions per Table M1306.2.

    International Residential Code, 2024 · Chapter 18, Chimneys and VentsRead the full text (opens UpCodes in a new tab)

  • R403.1

    General

    • Exterior walls sit on continuous concrete, solid or grouted masonry, crushed stone or wood footings bearing on undisturbed soil or engineered fill.
    • Concrete footing size comes from the tables by roof load, stories, foundation type, wall type and soil bearing value; widths may be interpolated between soil values but not extrapolated.
    • Add 2 in of width and 1 in of depth for every 4 ft the building is wider than 32 ft; narrower buildings may take the same off, down to 12 x 6 in.

    International Residential Code, 2024 · Chapter 4, FoundationsRead the full text (opens UpCodes in a new tab)

  • E4207.3.2

    Over the Low-Voltage Contact Limit but Not Over 150 Volts

    • Line-voltage storable pool lights up to 150 V are listed polymeric assemblies with integral open-neutral GFCI (NEC 680.33(B)).

    International Residential Code, 2024 · Chapter 42, Swimming PoolsRead the full text (opens UpCodes in a new tab)

  • E3403.3

    Listing and Labeling

    • Electrical products are listed or identified, labelled, and used per their listing (NEC 110.3(B)).

    International Residential Code, 2024 · Chapter 34, General RequirementsRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application