Skip to content

Search the building code.

Every 2024 IRC section and the IBC as it loads, by number or topic, plus the local rules for your city. Free to search.

Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

A random sample from 4,296 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • E3801.3

    Circuit Conductors

    • All of a circuit's conductors, grounding and bonding included, run in the same raceway, trench, cable or cord (NEC 300.3(B)).

    International Residential Code, 2024 · Chapter 38, Wiring MethodsRead the full text (opens UpCodes in a new tab)

  • R325.1.2

    Natural Ventilation

    • Habitable rooms can open to the outdoors over at least 4% of their floor area, unless mechanical ventilation is provided.
    • Vent openings may open to a porch at least 40% open, or to a sunroom with an opening of at least a tenth of the room's area and 20 sq ft.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

  • P2911.7.1

    Location

    • Reuse tanks keep set distances: 2 ft from protected tree roots, 5 ft from lot lines, septic and seepage pits and water service, 10 ft from public mains, 50 ft from wells and streams.

    International Residential Code, 2024 · Chapter 29, Water Supply and DistributionRead the full text (opens UpCodes in a new tab)

  • R703.3.3

    Fasteners

    • Siding nails and staples are corrosion-resistant (ASTM F1667), staples 16-gauge with a 7/16 in crown; through foam, fiberboard or gypsum they hit studs, and into 7/16 in panels they can follow the sheathing-only schedule.

    International Residential Code, 2024 · Chapter 7, Wall CoveringRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.