Over or within 5 ft of an indoor spa, lights and fans are at least 7 ft 6 in up and GFCI (none needed at 12 ft or more); lower enclosed damp-rated fixtures are allowed with GFCI (NEC 680.43(B)).
Under-floor wood needs treated or durable lumber when joists are within 18 in of the ground, girders 12 in or columns 8 in.
Siding, sheathing and framing need decay protection if closer than 6 in to soil or 2 in above an exposed slab or step.
Decay protection is also needed for framing within 8 in of ground on foundation walls, sills on ground slabs without a barrier, girder pockets under 1/2 in clearance, weather-exposed members and basement columns not on a 1 in pedestal.
The air intake draws from outdoors or a naturally vented crawl or attic, not from the garage or basement, sits no higher than the firebox (unless listed), and has a 1/4 in corrosion-resistant screen.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.
Check your plans against these codes
Start an application and get every flag with its section and fix.