Multiple CO alarms are interconnected (wireless is fine); existing areas are exempt unless finishes are opened or an attic, crawl or basement gives access.
Dishwashers, ranges, wall ovens, cooktops, dryers, microwaves, sump pumps, pressure washers and water coolers up to 150 V to ground and 60 A get GFCI protection (NEC 210.8(D)).
Local review: GFCI coverage here follows the 2023 NEC; confirm San Antonio's adopted NEC edition before relying on the expanded list.
Switches in recessed boxes seat their plaster ears on the wall; flush boxes seat the yoke on the box; mounting screws are listed or 32 TPI machine screws (NEC 404.10(B)).
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.