Each wall counter 12 in or wider gets a receptacle, with no point more than 24 in from one; none needed behind a range or sink per the figure (NEC 210.52(C)(1)).
125 V, 15 and 20 A receptacle outlets are provided per E3901.2 to E3901.11, not counting ones in luminaires, appliances, cabinets, switched outlets or over 5.5 ft high; baseboard-heater receptacles may count (NEC 210.52).
Hydronic piping is tested with water at 1.5 times design pressure (100 psi minimum) for 15 minutes; PEX may be air-tested only where every manufacturer allows it.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.