  • M2101.10

    Tests

    • Hydronic piping is tested with water at 1.5 times design pressure (100 psi minimum) for 15 minutes; PEX may be air-tested only where every manufacturer allows it.

    International Residential Code, 2024 · Chapter 21, Hydronic PipingRead the full text (opens UpCodes in a new tab)

  • G2401.1

    Application

    • Covers fuel gas piping from the point of delivery to appliance shutoffs, gas appliances, venting and combustion air in homes; anything not covered follows the IFGC. Excludes LNG, temporary LP, utility piping, portable appliances and vehicle fuel systems.

    Local review: San Antonio enforces fuel gas rules through its adopted fuel gas code with local amendments, and CPS Energy sets meter and service requirements; check both before relying on these model values.

    International Residential Code, 2024 · Chapter 24, Fuel GasRead the full text (opens UpCodes in a new tab)

  • G2414.4.3

    Copper or Copper-Alloy Tubing

    • Copper tubing is Type K or L (ASTM B88 or B280), not used with gas over 0.3 grains hydrogen sulfide per 100 scf.

    International Residential Code, 2024 · Chapter 24, Fuel GasRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.