Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

A random sample from 4,296 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • R502.1.1.2

    End-Jointed Lumber

    • Graded finger-jointed lumber can stand in for solid lumber of the same species and grade; in fire-rated assemblies it must be marked HRA.

    International Residential Code, 2024 · Chapter 5, FloorsRead the full text (opens UpCodes in a new tab)

  • G2401.1

    Application

    • Covers fuel gas piping from the point of delivery to appliance shutoffs, gas appliances, venting and combustion air in homes; anything not covered follows the IFGC. Excludes LNG, temporary LP, utility piping, portable appliances and vehicle fuel systems.

    Local review: San Antonio enforces fuel gas rules through its adopted fuel gas code with local amendments, and CPS Energy sets meter and service requirements; check both before relying on these model values.

    International Residential Code, 2024 · Chapter 24, Fuel GasRead the full text (opens UpCodes in a new tab)

  • G2427.10.5

    Clearance

    • Connector clearances by appliance and material: single-wall 6 in for listed draft-hood appliances, 9 in for conversion burners and Type L appliances, 18 in for other low-heat, 36 in medium-heat.

    International Residential Code, 2024 · Chapter 24, Fuel GasRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.