A random sample from 4,296 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • R402.3.1

    Precast Concrete Foundation Materials

    • Precast foundation concrete reaches 5,000 psi at 28 days (5% air if it freezes), with Grade 40 or better rebar and at least 3/4 in of cover.

    International Residential Code, 2024 · Chapter 4, FoundationsRead the full text (opens UpCodes in a new tab)

  • G2440.4

    Combustion and Dilution Air Intakes

    • Non-direct-vent sauna heaters have the draft hood and air intake outside the sauna, protected or posted with 1/4 in warning lettering.

    International Residential Code, 2024 · Chapter 24, Fuel GasRead the full text (opens UpCodes in a new tab)

  • R301.2.1

    Wind Design Criteria

    • Wind design uses the mapped ultimate wind speed, but never less than the lowest speed the prescriptive tables cover.
    • Component and cladding design pressures are never taken below 10 psf, positive or negative.
    • A member's effective wind area is span times a width of at least a third of the span; for a fastener, no more than its tributary area.
    • The edge and corner pressure zones are 4 ft wide on every building, and an overhang adds its roof zone and adjacent wall zone pressures together.
    • Multiply the base cladding pressures by this factor for mean roof height and exposure.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

  • R702.1

    General

    • Plaster thickness depends on the base: 5/8 in over metal lath, 1/2 in over gypsum lath or masonry for gypsum plaster; cement plaster 3/4 in interior and 7/8 in exterior over wire lath or sheathing.

    International Residential Code, 2024 · Chapter 7, Wall CoveringRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application