  • N1108.2.1.3

    Roof Solar Reflectance Index

    • Low-slope roofs in zones 0-2 earn credit with a 3-year aged SRI of 75 or more over 95 percent of the roof, excluding PV, equipment, shaded and ballasted areas.

    International Residential Code, 2024 · Chapter 11, Energy EfficiencyRead the full text (opens UpCodes in a new tab)

  • R403.3

    Frost-Protected Shallow Foundations

    • Heated buildings kept at 64°F or more may use insulated shallow footings instead of going below frost; not for unheated porches, garages or crawl spaces.
    • Shallow footing depth and insulation step up with the air-freezing index; horizontal insulation starts at 2,500 °F-days.
    • Rate foam by its long-term wet R-value per inch: EPS Type II 3.2 vertical and 2.6 horizontal, Type IX 3.4 and 2.8, XPS 4.5 and 4.0.
    • Every Texas county is in the lowest air-freezing band (1,500 °F-days or less).

    International Residential Code, 2024 · Chapter 4, FoundationsRead the full text (opens UpCodes in a new tab)

  • P3008.2

    Allowable Installations

    • Backwater valves on floors above the manhole cover are normally-open type, except existing buildings.

    International Residential Code, 2024 · Chapter 30, Sanitary DrainageRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.