A random sample from 4,296 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • R321.1.1

    Where Required

    • A guard is needed wherever an open side drops more than 30 in within 36 in of its edge; insect screen doesn't count.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

  • P3009.9

    Subsurface Graywater Soil Absorption System Site Location

    • Absorption sites sit downhill of wells, stay set distances away (tank and field: 5 and 2 ft from buildings, 50 and 100 ft from wells, 10 ft from mains), never under driveways, with surface water diverted.

    International Residential Code, 2024 · Chapter 30, Sanitary DrainageRead the full text (opens UpCodes in a new tab)

  • R802.5.2

    Ceiling Joist and Rafter Connections

    • Ceiling joists in the bottom third of the rafter height are nailed to the rafters per the heel joint table; higher joists, or joists running the other way without rafter ties, require a beam ridge.
    • Heel nailing rises as ties move up: x1.11 at 1/10 of the rise or less, up to x1.5 at one-third; above a third, the connection is designed.

    International Residential Code, 2024 · Chapter 8, Roof-Ceiling ConstructionRead the full text (opens UpCodes in a new tab)

  • M1408.4

    Access

    • Floor furnace access is an 18 x 24 in foundation opening or a 22 x 30 in trap door, big enough to replace any part.

    International Residential Code, 2024 · Chapter 14, Heating and Cooling Equipment and AppliancesRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.