Methods of Grounding Conductor Connection to Electrodes
GECs connect to electrodes by exothermic welding or listed lugs, connectors or clamps rated for burial where buried; no solder, one conductor per clamp unless listed (NEC 250.70(A)).
Condensate pipe is ABS, cast iron, copper, PEX, CPVC, galvanized, PE-RT, PE, PP or PVC, at least 3/4 in from pan to disposal; manifolded drains are sized by an approved method.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.