Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).
18 sections matching “IBC 504” for San Antonio, TX, the 2024 IRC
IBC 504.1
General
Allowable height and stories depend on construction type, occupancy and sprinklers. One-story aircraft hangars and aircraft plants with suppression and surrounding yards of 1½ × height are unlimited.
Height above grade plane is limited by Table 504.3. Combustible rooftop towers and spires may rise up to 20 ft above the limit; noncombustible ones are unlimited.
Groups A, B, E, F, M, S, U and R: unsprinklered IA unlimited, IB 160, IIA 65, IIB 55, IIIA 65, IIIB 55, IV 65, VA 50, VB 40; fully sprinklered (13) IA unlimited, IB 180, IIA 85, IIB 75, IIIA 85, IIIB 75, IV-A 270, IV-B 180, IV-C 85, IV-HT 85, VA 70, VB 60. Group R with 13R is 60 ft in every type.
Height, stories and area may not exceed Sections 504 and 506 for the construction type (602) and occupancy (302); each is checked separately, and each part separated by fire walls counts as its own building.
Asphalt shingles are tested to ASTM D7158 (or D3161) and classed per Table 1504.2: up to 116 mph D, G or H; 129–155 mph G or H; 168 mph and up H (D3161: A, D or F to 129 mph, F above).
Aggregate-surfaced roofs need perimeter parapets per Table 1504.8 by gravel size, roof height, exposure and wind speed (e.g. No. 7 gravel, 30 ft roof, Exposure C, 115 mph: 24 in). Exposure D adds 8 in.
An occupiable roof may only hold an occupancy allowed by Table 504.4 on the story below; it doesn't count toward area, height or stories if rooftop structures meet 1511. Fully sprinklered buildings with roof notification may use any occupancy.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.