14 sections matching “IBC 407.4.4” for San Antonio, TX, the 2024 IRC

  • IBC 407.4.4.1

    Exit access through care suites

    • Other areas may not exit through a care suite.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.4.4.3

    Access to corridor

    • Each care suite has a door to a corridor or horizontal exit within 100 ft of travel.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.4.4.4

    Circulation paths within a care suite

    • Paths within a care suite are at least 36 in wide.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.4.4.6

    Care suites containing sleeping room areas

    • Sleeping suites serve 8 or fewer beds, allow constant visual supervision, or have smoke detection.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.4.4.7

    Care suites not containing sleeping rooms

    • Treatment-only suites follow 407.4.4.7.1 and 407.4.4.7.2.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.4.4.6.1

    Area

    • Sleeping suites up to 7,500 sq ft, or 10,000 with smoke detection.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.4.4.7.1

    Area

    • Treatment suites up to 12,500 sq ft, or 15,000 with smoke detection.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 202

    Care suite

    • In Group I-2, a group of treatment and sleeping rooms with support and circulation space, where staff supervise all care recipients, meeting 407.4.4.

    Works withIBC 407.4.4

    International Building Code, 2024 · Chapter 2, DefinitionsRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.