Every 2024 IRC section and the IBC as it loads, by number or topic, plus the local rules for your city. Free to search.
Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).
13 sections matching “IBC 1705.13” for San Antonio, TX, the 2024 IRC
IBC 1705.13
Special inspections for seismic resistance
Seismic special inspections per 1705.13.1–1705.13.9; exempt light-frame with SDS ≤ 0.5 and height ≤ 35 ft, reinforced masonry/concrete with SDS ≤ 0.5 and ≤ 25 ft, and regular one- and two-family dwellings of two stories or less.
Seismic (SDC C–F): continuous inspection of field gluing; periodic for wood shear wall and diaphragm fastening unless edge nailing is more than 4 in o.c.
SDC D–F: periodic inspection of cladding, nonbearing walls and veneer, except under 30 ft high, veneer 5 psf or less, or interior walls 15 psf or less.
Periodic inspection of anchorage of emergency electrical equipment, hazardous piping and ducts, vibration isolators, and sprinkler clearances (3 in) in SDC C–F.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.