Every 2024 IRC section and the IBC as it loads, by number or topic, plus the local rules for your city. Free to search.

Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

17 sections matching “IBC 508.4” for San Antonio, TX, the 2024 IBC

  • IBC 508.4

    Separated occupancies

    • Buildings meeting this section are separated occupancies, divided per Table 508.4.
    • Sprinklered building examples: R to A, E, B, M, S-1, S-2 or U is 1 hour; A/E to B, M, S-1 1 hour; A/E to S-2/U none; B/F-1/M/S-1 to each other none; I-2 to most groups 2 hours; H-2 3 hours from A, B, R. Unsprinklered values are one hour higher or not permitted. Separations from areas used only for private vehicles drop 1 hour (not below 1).

    Works withIBC Table 508.4IBC 420IBC 406.3.2

    International Building Code, 2024 · Chapter 5, General Building Heights and AreasRead the full text (opens UpCodes in a new tab)

  • IBC 508.4.1

    Occupancy classification

    • Each separated space follows its own occupancy; Chapter 9's most restrictive rule applies across areas not split by fire barriers; fire-area separations also meet 901.7.

    Works withIBC 901.7

    International Building Code, 2024 · Chapter 5, General Building Heights and AreasRead the full text (opens UpCodes in a new tab)

  • IBC 508.4.2

    Allowable building area

    • In each story, the sum of (actual area ÷ allowable area) for each separated occupancy may not exceed 1.

    International Building Code, 2024 · Chapter 5, General Building Heights and AreasRead the full text (opens UpCodes in a new tab)

  • IBC 508.4.4.1

    Construction

    • Separations are fire barriers (707) and/or horizontal assemblies (711); exposed mass timber in IV-B/IV-C separations needs a ½-in gypsum thermal barrier.

    Works withIBC 707IBC 711

    International Building Code, 2024 · Chapter 5, General Building Heights and AreasRead the full text (opens UpCodes in a new tab)

  • IBC 507.9

    Unlimited mixed occupancy buildings with Group H-5

    • Two-story sprinklered B, F, H-5, M or S with 60-ft yards is unlimited if H-5 is Type I/II, separated per 415.11 and 508.4, and within its allowable area (or split by 2-hour barriers).

    Works withIBC 415.11IBC 508.4

    International Building Code, 2024 · Chapter 5, General Building Heights and AreasRead the full text (opens UpCodes in a new tab)

  • IBC 506.2.2

    Mixed-occupancy buildings

    • Mixed buildings use 508.3.2 or 508.4.2 per story; above three stories the sum of each story's actual/allowable ratios may not exceed 3 (4 with 13R and separated occupancies).

    Works withIBC 508.3.2IBC 508.4.2

    International Building Code, 2024 · Chapter 5, General Building Heights and AreasRead the full text (opens UpCodes in a new tab)

  • IBC 507.4.1

    Mixed occupancy buildings with Groups A-1 and A-2

    • A-1 and A-2 (not Type V) may be in a 507.4 building if separated per 508.4.4 without sprinkler reduction, each within its own allowable area, with exits directly outside.

    Works withIBC 508.4.4

    International Building Code, 2024 · Chapter 5, General Building Heights and AreasRead the full text (opens UpCodes in a new tab)

  • IBC 508.2.4

    Separation of occupancies

    • No separation is needed between accessory and main occupancies, except H-2 to H-5 (508.4) and dwelling/sleeping units (420).

    Works withIBC 508.4IBC 420

    International Building Code, 2024 · Chapter 5, General Building Heights and AreasRead the full text (opens UpCodes in a new tab)

  • IBC 510.7.1

    Fire separation

    • Separate garage and upper occupancy per Table 508.4; supporting garage members carry the stricter rating; upper egress is enclosed by 2-hour barriers.

    Works withIBC 508.4IBC 601

    International Building Code, 2024 · Chapter 5, General Building Heights and AreasRead the full text (opens UpCodes in a new tab)

  • IBC 506.2.2.1

    Group H-2 or H-3 mixed occupancies

    • With H-2 or H-3 present, use 508.4.2 and apply the sprinkler increase only to non-H-2/H-3 parts.

    Works withIBC 508.4.2

    International Building Code, 2024 · Chapter 5, General Building Heights and AreasRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.