27 sections matching “IBC 410” for San Antonio, TX, the 2024 IBC

  • IBC 410.1

    Applicability

    • Applies to buildings with stages, platforms and technical production areas.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 410.3

    Platform construction

    • Permanent platforms match the construction type; FRT wood allowed up to 30 in high and 3,000 sq ft; storage beneath needs 1-hour floors.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 410.4

    Dressing and appurtenant rooms

    • Dressing and support rooms follow 410.4.1 and 410.4.2.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 410.5

    Means of egress

    • Chapter 10 applies except as modified.

    Works withIBC Chapter 10

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 410.6

    Automatic sprinkler system

    • Stages are sprinklered under roof, gridiron and catwalks and in support rooms; small stages without rising scenery excepted.

    Works withIBC 903.3.1.1

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 410.2.1

    Stage construction

    • Stages are built like floors for the construction type, with exceptions for 2-in wood decks and sprinklered below-stage spaces.

    Works withIBC 903IBC 904

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 410.2.2

    Technical production areas: galleries, gridirons and catwalks

    • Gridirons and catwalks needn't be rated and aren't floors, stories or mezzanines.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 410.2.3

    Exterior stage doors

    • Protected exterior stage doors are fire doors; often-open stage openings need vestibules.

    Works withIBC 716

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 410.2.5

    Proscenium curtain

    • Rated proscenium openings need a fire curtain, 1-hour sliding doors, water curtain, or smoke control.

    Works withIBC 716IBC 909

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 410.2.7

    Stage ventilation

    • Stages over 1,000 sq ft or 50 ft high need emergency ventilation.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 410.3.1

    Temporary platforms

    • Platforms up 30 days or less may be any material; space beneath only for wiring and plumbing.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 410.5.2

    Stairway and ramp enclosure

    • Stairs serving stages, platforms and production areas needn't be enclosed.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 410.5.3

    Technical production areas

    • Production areas get egress per 410.5.3.1 to 410.5.3.5.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 410.2.1.1

    Stage height and area

    • Stage area includes unseparated backstage; height runs from lowest stage floor to the deck above.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 410.2.7.2

    Smoke control

    • Smoke control keeps smoke 6 ft above the highest seating or the proscenium top.

    Works withIBC 909

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 410.5.3.2

    Exit access travel distance

    • Travel limited to 300 ft unsprinklered, 400 ft sprinklered.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 410.5.3.3

    Two means of egress

    • Common path up to 100 ft; roof escape may replace the second exit.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 410.5.3.4

    Path of egress travel

    • Stairs, ramps, spiral stairs, catwalks, alternating tread devices and ladders allowed.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.