8 sections matching “IBC 406.7” for San Antonio, TX, the 2024 IBC

  • IBC 406.7

    Motor fuel-dispensing facilities

    • Fuel stations follow the IFC, 406.2 and 406.7.

    Works withIFC

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 406.7.1

    Vehicle fueling pad

    • Fueling pads are uncoated concrete or paving of 1 megohm or less resistance.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 406.7.2

    Canopies

    • Fuel canopies have 13 ft 6 in clear and are noncombustible, FRT wood, heavy timber or 1-hour; plastics limited (light-transmitting panels up to 100 sq ft each, 1,000 total).

    Works withIBC 2304.11

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 406.7.2.1

    Canopies used to support gaseous hydrogen systems

    • Canopies carrying hydrogen are Type I, refueling only, and shaped so hydrogen can't collect.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 406.1

    General

    • Motor-vehicle occupancies meet 406.2, plus 406.3 (private), 406.4–406.6 (public garages), 406.7 (fuel) and 406.8 (repair).

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.