A random sample from 729 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • P3104.5

    Height Above Fixtures

    • Vent connections to stacks and horizontal branch vents are at least 6 in above the highest fixture rim served.

    International Residential Code, 2024 · Chapter 31, VentsRead the full text (opens UpCodes in a new tab)

  • P2603.5

    Freezing

    • Where the winter design temperature is 32 F or lower, pipes outside, in exterior walls, attics or crawl spaces are protected from freezing; water service is at least 12 in deep and 6 in below the frost line.

    Local review: San Antonio's winter design temperature is roughly 30 F, so the freeze-protection rule applies; confirm the frost depth the city publishes for water service burial.

    International Residential Code, 2024 · Chapter 26, General Plumbing RequirementsRead the full text (opens UpCodes in a new tab)

  • P2906.4.1

    Separation of Water Service and Building Sewer

    • Water service and sewer share a trench only if the sewer is Table P3002.1(2) material; otherwise 5 ft apart, sleeved 5 ft each side at crossings, or the water line 12 in above.

    International Residential Code, 2024 · Chapter 29, Water Supply and DistributionRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application