No running threads, bands, drilling, tapping, burning or welding of DWV; no cement, mastic, unapproved fittings, rolling O-rings between sizes, solvent welds between different plastics, or saddle fittings.
Subsoil (foundation) drains are perforated or open-joint pipe at least 4 in, with a backwater valve where backwater is possible, discharging to a trapped drain, sump, dry well or daylight; subsoil sumps need no gastight cover or vent.
Gaps around pipes through sleeves or envelope walls, floors and ceilings are sealed with compatible caulk, foam or gaskets; rated assemblies follow the building code.
Horizontal to Vertical (Multiple Connection Fittings)
Double fittings at one level need equal-size opposing inlets from similar fixtures; double sanitary tees can't take back-to-back toilets or pumped discharge unless the toilets are 18 in from the tee.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.
Check your plans against these codes
Start an application and get every flag with its section and fix.