Minimum plumbing fixtures per Table 2902.1 by use, e.g. business WC 1 per 25 for the first 50 then 1 per 50; restaurants 1 per 75; mercantile 1 per 500; educational 1 per 50; apartments 1 per unit plus a washer hookup per 20 units.
Toilets, urinals, lavatories and bidets 15 in from center to side walls, 30 in center to center, 21 in clear in front; WC compartments 30×60 in (30×56 wall-hung).
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.