  • M1601.1.1

    Above-Ground Duct Systems

    • Above-ground ducts: discharge air 250 F max; factory ducts UL 181; fiberglass per SMACNA or NAIMA; metal and flex per SMACNA (or the thin-gauge table); materials flame spread 200 max; balancing dampers accessible.
    • Stud and joist cavities may be return plenums only: never supply, not in rated assemblies or exterior walls, one floor per stud cavity, fireblocked from other spaces, and sealed.

    International Residential Code, 2024 · Chapter 16, Duct SystemsRead the full text (opens UpCodes in a new tab)

  • G2414.9.1

    Pipe Joints

    • Schedule 40 and heavier pipe is threaded, flanged, brazed, welded or LC4 press-fit; thinner pipe skips threading; brazing above 1,000 F with 0.05 percent phosphorus max.

    International Residential Code, 2024 · Chapter 24, Fuel GasRead the full text (opens UpCodes in a new tab)

  • M1307.3.1

    Protection From Impact

    • Appliances are kept out of vehicle paths unless protected by approved barriers.

    International Residential Code, 2024 · Chapter 13, General Mechanical System RequirementsRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.