Show another sample
  • M2201.3

    Underground Tanks

    • Underground tanks don't undermine foundations, sit 1 ft from basements, pits and lot lines, are bedded in tamped sand or gravel, covered by 1 ft of earth, and corrosion-protected.

    International Residential Code, 2024 · Chapter 22, Special Piping and Storage SystemsRead the full text (opens UpCodes in a new tab)

  • M2301.2.6

    Protection From Freezing

    • Components are protected from freezing at the Table R301.2 winter design temperature per SRCC 300, unless the 97.5 percent design temperature is 48 F or higher.

    Local review: San Antonio's 97.5 percent winter design temperature is roughly 30 F, below the 48 F exemption, so freeze protection is required; confirm the value in the city's Table R301.2 entries.

    International Residential Code, 2024 · Chapter 23, Solar Thermal Energy SystemsRead the full text (opens UpCodes in a new tab)

  • G2414.9.1

    Pipe Joints

    • Schedule 40 and heavier pipe is threaded, flanged, brazed, welded or LC4 press-fit; thinner pipe skips threading; brazing above 1,000 F with 0.05 percent phosphorus max.

    International Residential Code, 2024 · Chapter 24, Fuel GasRead the full text (opens UpCodes in a new tab)

  • M1804.3.1

    Size of Single-Appliance Venting Systems

    • A single-appliance vent is at least the connector's area and at least 7 sq in, unless integral to a listed appliance.

    International Residential Code, 2024 · Chapter 18, Chimneys and VentsRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application