Skip to content

Search the building code.

Every 2024 IRC section and the IBC as it loads, by number or topic, plus the local rules for your city. Free to search.

Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

A random sample from 235 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • N1102.4.2

    Glazed Fenestration SHGC

    • SHGC may be area-weighted over products more than half glazed; dynamic glazing counts if its high-to-low SHGC ratio is 2.4 or more and it is automatically controlled, and it is not averaged with other glass.

    International Residential Code, 2024 · Chapter 11, Energy EfficiencyRead the full text (opens UpCodes in a new tab)

  • N1102.2.9

    Basement Walls

    • Basement walls are insulated per the table unless the basement is unconditioned with an insulated floor above, no exposed ducts, pipes or registers, and insulated, sealed stair walls and doors.

    International Residential Code, 2024 · Chapter 11, Energy EfficiencyRead the full text (opens UpCodes in a new tab)

  • N1106.6

    Verification by Approved Agency

    • ERI results are verified by an approved third party; mandatory items by the official or approved inspector.

    International Residential Code, 2024 · Chapter 11, Energy EfficiencyRead the full text (opens UpCodes in a new tab)

  • N1108.2.3

    Reduced Energy Use in Service Water-Heating Options

    • Water heating credits need the tabled UEF: gas storage 0.81 or 0.86, gas tankless 0.92 or 0.95, heat pump 2.20 to 3.75, solar SUEF 3.00 (electric backup) or 1.80 (gas).

    International Residential Code, 2024 · Chapter 11, Energy EfficiencyRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application