An above-code program the official accepts counts as compliance if the Table N1105.2 items are met, envelope TC stays within 1.08x (zones 0-2) or 1.15x (zones 3-8) of prescriptive, and SHGC is 0.30 max in zones 0-3.
Prescriptive homes earn at least 10 credits from at least two measures in Table N1108.2, plus 5 more over 5,000 sq ft above grade; no interpolating between measures.
Local review: Cities often amend the additional-credit requirement; confirm whether San Antonio's adopted energy code includes it and how many credits it requires.
Use Figure or Table N1101.7 to find the climate zone by county; unlisted places use N1101.7.2. Moisture letters are A moist, B dry, C marine; an asterisk marks Warm Humid.
Local review: San Antonio is in Bexar County, climate zone 2A and Warm Humid. Nearby counties differ (Kendall 3A, Medina 2B), so check the county for sites outside the city.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.
Check your plans against these codes
Start an application and get every flag with its section and fix.