Prescriptive homes earn at least 10 credits from at least two measures in Table N1108.2, plus 5 more over 5,000 sq ft above grade; no interpolating between measures.
Local review: Cities often amend the additional-credit requirement; confirm whether San Antonio's adopted energy code includes it and how many credits it requires.
Crawl wall insulation runs from the sill to the top of the footing (or the crawl floor if over 24 in below grade), and exposed earth gets a sealed Class I vapor retarder lapped 6 in and run 6 in up the walls.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.