SHGC may be area-weighted over products more than half glazed; dynamic glazing counts if its high-to-low SHGC ratio is 2.4 or more and it is automatically controlled, and it is not averaged with other glass.
More Efficient Thermal Distribution System Options
Distribution credits: ductless or hydronic inside, all ducts and equipment inside, at least 80 percent inside, low duct leakage (2.0 or 1.75 cfm/100 sq ft), or room airflow balanced within 20 percent.
Access hatches and doors to attics and crawl spaces are insulated like the surrounding assembly; in zones 0-4 pull-down stairs may be R-10 average (R-13 over 75 percent), 13.5 sq ft max, weatherstripped.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.