In unfinished basements and crawl spaces, NM/SE cable of 2-#6 or 3-#8 and larger may run on joist bottoms; smaller goes through bores or running boards; wall runs may be sleeved, sheath 1/4 in into the box and secured within 12 in (NEC 334.15(C)).
Connecting Receptacle Grounding Terminal to an Equipment Grounding Conductor
A bonding jumper connects the receptacle ground to a grounded metal box, except surface boxes with direct contact, listed self-grounding yokes or listed floor boxes (NEC 250.146).
Chapter 37 covers branch circuits and feeders serving less than the whole dwelling load; a feeder carrying the whole load is sized like a service (NEC 310.12(B)).
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.