A random sample from 677 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • E3901.9

    Basements, Garages and Accessory Buildings

    • At least one receptacle in each unfinished basement portion, each garage vehicle bay (no higher than 5.5 ft) and each powered accessory building; a security-system-only receptacle doesn't count (NEC 210.52(G)).

    International Residential Code, 2024 · Chapter 39, Power and Lighting DistributionRead the full text (opens UpCodes in a new tab)

  • E4003.6

    Thermal Protection

    • Indoor fluorescent ballasts have integral thermal protection, replacements too (NEC 410.130(E)).

    International Residential Code, 2024 · Chapter 40, Devices and LuminairesRead the full text (opens UpCodes in a new tab)

  • E3906.8.5

    Raceway Supported Enclosures, With Devices or Luminaire

    • A raceway-supported box with a device or luminaire is 100 cu in max, held by two threaded conduits secured within 18 in; a single RMC/IMC may hold a light under strict limits (NEC 314.23(F)).

    International Residential Code, 2024 · Chapter 39, Power and Lighting DistributionRead the full text (opens UpCodes in a new tab)

  • E3604.3

    Point of Attachment

    • The point of attachment keeps the required clearances and is at least 10 ft above finished grade (NEC 230.26).

    Local review: CPS Energy sets its own meter, service-drop and point-of-attachment requirements in San Antonio; check its service standards alongside these.

    International Residential Code, 2024 · Chapter 36, ServicesRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.